Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | LN |
Model Number : | DKFXRS-9I/CY |
Certification : | CE ISO CCC |
Price : | Negotiable |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 80000pcs/year |
Delivery Time : | 1-30 working days |
Heat Pump Water Heater Hot Water System Air Source Heat Pumps Inverter Air to Water Heat Pump,is operating steadily under -30℃~45℃ ambient temperature,for cold regions Heating in Winter ,Cooling in Summer, and with 5 optional functions: Domestic hot water,Heating Cooling, Heating&Hot Water,Cooling&Hot Water.
The heat pump type double-effect negative pressure solid-liquid separation unit system belongs to the technical field of solid-liquid separation unit structure. It includes a heating chamber with a feed inlet and a discharge port. A heat pump condenser for full contact with the solid-liquid mixture is installed in the heating chamber. The heat pump condenser is connected to the heat pump through a circulating pipeline, and the heat pump is also connected to a moisture condensation chamber. The moisture condensing chamber is connected with a vacuum pump system for vacuuming. The heat pump is also connected with two first heat pump evaporators and second heat pump evaporators for absorbing heat energy in the moisture condensing chamber and the air. The first heat pump evaporator is sealed and installed in In the moisture condensation chamber, one port of the heating chamber is connected to the moisture evaporation chamber through a circulating pump, and the other port is connected to the moisture evaporation chamber through a circulating pipeline. The utility model has reasonable structural design, high efficiency, environmental protection and no emission, good solid-liquid separation effect, and can effectively save energy.
Applicable places: places such as factory dormitories, hotels, schools, hospitals,
apartments, beauty salons, villas, swimming pool constant
temperature, breeding constant temperature, high temperature hot
water of electroplating factory, high temperature hot water of
slaughterhouse, etc.
Advantages: Compared with traditional water heaters, it is energy-saving and
environmentally friendly, safe and reliable, and is not limited by
the installation site.
Features: Fully automatic control, small footprint
Strength of Leomon Heat Pump Water Heater Hot Water System Air Source Heat Pumps
Air energy heat pumps are different from traditional hot water
machines. Air energy heat pumps are the fourth generation of new
energy heating products, which achieve energy-saving and safe
heating effects through the extensive use of free air energy.
The air-energy heat pump heating mode is also different from the
traditional method. It is no longer completely dependent on a
single energy source, and uses a new type of clean energy-air
energy. The air energy unit converts low-temperature air into
high-temperature and high-pressure heat through multiple processes
such as compressor unit, evaporator, and heat exchange, and
transfers it to the water tank to heat the cold water.
80% of the energy of the air heat pump is air, and the remaining
electric energy is used to drive the operation of the unit. The air
heat pump converts free air into energy, which saves 75% of the air
heat pump unit compared with the traditional motor unit. Heating
cost. The air energy heat pump uses a large amount of air energy,
and only a quarter of the electric energy is enough to produce more
high-temperature hot water, which will greatly extend the time that
users use hot water and increase the water output of the air energy
heat pump. .
The air energy heat pump does not use fuel for heating. There are
only two types of energy sources: air and electricity. In terms of
heating, explosion accidents and poisoning accidents are avoided.
The heating activity in the water tank does not involve power
supply, so the heat pump The unit can prevent electric shock safety
hazards and create a safe hot water space for users.
Some technical paremeters for Instant Hot Water Heater Provided Air
Source Exchange Heat Pump Air To Water HVAC System
Spec. | KRY-24II | KRY-48II | KRY-96II |
Rated heating capacity(A24/26oC) | 24kw | 48kw | 96kw |
Rated power(kW) | 4.7 | 9.3 | 18.5 |
COP | 5.1 | 5.16 | 5.41 |
Rated heating capacityA20/26oC | 21kw | 44 kw | 90kw |
Rated power(kW) | 4.5 | 8.6 | 17.5 |
COP | 4.66 | 5.11 | 5.14 |
Cooling Capacity(kW) | 11.3 | 23.7 | 40 |
Consumed Power(kW) | 4.9 | 9.1 | 18.2 |
EER | 2.3 | 2.6 | 2.2 |
Rated voltage(Hz) | 380V 3N-50HZ | 380V 3N-50HZ | 380V 3N-50HZ |
The compressor | ZW61KA-TFP-52E(one sets ) | ZW61KA-TFP-52E(two sets ) | ZW61KA-TFP-52E(four sets ) |
Fan Quantity | 1 | 2 | 4 |
Fan Quantity(W) | 370×1 | 370×2 | 370×4 |
Fan speed(rpm) | 850 | 850 | 850 |
Maximum input power(kW) | 6 | 12 | 24 |
Maximum current(A) | 24 | 42 | 80 |
Water flownWh | 7 | 13 | 32 |
noise dB(A) | <65 | <68 | <69 |
Anti-shock level | I | I | I |
waterproof level | IPV4 | IPV4 | IPV4 |
Unit size (mm) | 780x820x1700 | 1550x780x1700 | 1550x1550x1700 |
Unit Weight(kg) | 260 | 380 | 760 |
Rated heating conditions: outdoor dry/wet bulb temperature is 24°C/19°C, hot water inlet temperature is 26°C, outlet water temperature is 28°C; | |||
Rated heating conditions: outdoor dry/wet bulb temperature is 20°C/15°C, hot water inlet temperature is 26°C, outlet water is 28°C; | |||
Rated Cooling conditions: outdoor dry/wet bulb temperature is 35°C, COOL water inlet temperature is 30°C, outlet water is 28°C. |
Compressor Info
Model | Refrigerant | Heating (kw) | Input power (KW) | Current (A) | Large running current (A) | Weight (kg) |
ZW61KA-TFP-52E | R22 | 21.86 | 3.12 | 9.6 | 14.4 | 30 |
![]() |